    Trinity Walk – Wakefield

    Trinity Walk – Wakefield

    Library Car Park Description The car park is on a single level, with an entry/exit. The car park entrance will provide the fresh air intake.   Next Service Yard Description This service yard is on a single level, with an entry/exit. The entrance will provide the fresh air intake.   Sainsbury’s Service Yard Description The

    • July

      8

      2010
    • 717
    • 0
    Honeypot Lane

    Honeypot Lane

    The car park is on a three levels with a single entry/exit ramp and interconnecting ramps. The ramps will serve as the route for fresh air supply along with openings to ENE elevation. Full Mechanical Ventilation A fully mechanical ventilation system, compliant with Approved Documents B & F of the current Building and designed in

    • November

      2

      2009
    • 1044
    • 0
    An Alldays Original

    An Alldays Original

    It’s always a pleasure when a striking reminder of our company’s great heritage lands on our doorstep.  A Mr K.R. Blake sent us this shot of a stunning 1912 Alldays Onions motorcycle that he has lovingly restored. Mr Blake tells us “It’s fitted with a 3 speed Sturmey Archer rear wheel hub and it goes

    • June

      8

      2009
    • 632
    • 0
    Pembury Hospital

    Pembury Hospital

    Car Park Description The car park is on three levels (the levels are split, but essentially there are three levels in terms of the car park ventilation) with a single entry/exit ramp. The ramp will serve as on route for fresh air supply, however the main fresh air supply is from the side of the

    • September

      8

      2007
    • 800
    • 0
    Snow Hill – Birmingham

    Snow Hill – Birmingham

    Car Park Description The car park is on four levels each with a single entry/exit ramp. The ramps will serve as one of the main route for fresh air supply along with supply louvers and dampers on the west side of the building.   Basis of System Design A fully mechanical ventilation system compliant with

    • August

      8

      2006
    • 779
    • 0
    GLASGOW HARBOURSIDE – Glasgow

    GLASGOW HARBOURSIDE – Glasgow

    The car park is on two levels with two entry/exit ramps and two interconnecting ramps between levels. The ramps will serve as one route for fresh air supply.   Whilst only one of the two levels is to be fully ventilated mechanically, the upper level (-1) will have sufficient natural ventilation for fire conditions, but